Document Type : Original Research

Authors

1 M.Sc. Student of Medical Physics, Tabriz University of Medical Science,Tabriz, Iran

2 Professor of Medical Physics and Engineering, Medical Physics Department, School of Medicine, Tabriz, Iran

3 Assistant Professor of Biomedical Engineering, Biomedical Physics and Biomedical Engineering Dept., Shiraz University of Medical Sciences, Shiraz, Iran

4 Associate Professor of Medical Physics, Radiology Department, School of Paramedical, Tabriz, Iran

Abstract

Background: Volume estimation of brain is important for many neurological applications. It is necessary in measuring brain growth and changes in brain in normal/abnormal patients. Thus, accurate brain volume measurement is very important. Magnetic resonance imaging (MRI) is the method of choice for volume quantification due to excellent levels of image resolution and between-tissue contrast. Stereology method is a good method for estimating volume but it requires to segment enough MRI slices and have a good resolution. In this study, it is desired to enhance stereology method for volume estimation of brain using less MRI slices with less resolution.Methods: In this study, a program for calculating volume using stereology method has been introduced. After morphologic method, dilation was applied and the stereology method enhanced. For the evaluation of this method, we used T1-wighted MR images from digital phantom in BrainWeb which had ground truth.Results: The volume of 20 normal brain extracted from BrainWeb, was calculated. The volumes of white matter, gray matter and cerebrospinal fluid with given dimension were estimated correctly. Volume calculation from Stereology method in different cases was made. In three cases, Root Mean Square Error (RMSE) was measured. Case I with T=5, d=5, Case II with T=10, D=10 and Case III with T=20, d=20 (T=slice thickness, d=resolution as stereology parameters). By comparing these results of two methods, it is obvious that RMSE values for our proposed method are smaller than Stereology method.Conclusion: Using morphological operation, dilation allows to enhance the estimation volume method, Stereology. In the case with less MRI slices and less test points, this method works much better compared to Stereology method.

Keywords

  1. Nair SSK, Revathy K, editors. Quantitative analysis of brain tissues from magnetic resonance images. Digital Image Processing, 2009 International Conference on; 2009: IEEE.
  2. Geuze E, Vermetten E, Bremner JD. MR-based in vivo hippocampal volumetrics: 1. Review of methodologies currently employed. Mol Psychiatry. 2005;10:147-59. doi.org/10.1038/sj.mp.4001580. PubMed PMID: 15340353.
  3. Hahn HK, Jolly B, Lee M, Krastel D, Rexilius J, Drexl J, et al., editors. How accurate is brain volumetry? International Conference on Medical Image Computing and Computer-Assisted Intervention; 2004: Springer.
  4. Giorgio A, De Stefano N. Clinical use of brain volumetry. Journal of Magnetic Resonance Imaging. 2013;37:1-14. doi.org/10.1002/jmri.23671.
  5. Karsch K, Grinstead B, He Q, Duan Y. Web based brain volume calculation for magnetic resonance images. Conf Proc IEEE Eng Med Biol Soc. 2008;2008:1210-3. doi.org/10.1109/iembs.2008.4649380. PubMed PMID: 19162883.
  6. Galinsky VL, Frank LR. Automated segmentation and shape characterization of volumetric data. Neuroimage. 2014;92:156-68. doi.org/10.1016/j.neuroimage.2014.01.053. PubMed PMID: 24521852. PubMed PMCID: 4324567.
  7. Scarpazza C, Tognin S, Frisciata S, Sartori G, Mechelli A. False positive rates in Voxel-based Morphometry studies of the human brain: should we be worried? Neurosci Biobehav Rev. 2015;52:49-55. doi.org/10.1016/j.neubiorev.2015.02.008. PubMed PMID: 25701614.
  8. Mills KL, Tamnes CK. Methods and considerations for longitudinal structural brain imaging analysis across development. Dev Cogn Neurosci. 2014;9:172-90. doi.org/10.1016/j.dcn.2014.04.004. PubMed PMID: 24879112.
  9. Keller SS, Roberts N. Measurement of brain volume using MRI: software, techniques, choices and prerequisites. J Anthropol Sci. 2009;87:127-51. PubMed PMID: 19663172.
  10. Steen RG, Hamer RM, Lieberman JA. Measuring brain volume by MR imaging: impact of measurement precision and natural variation on sample size requirements. AJNR Am J Neuroradiol. 2007;28:1119-25. doi.org/10.3174/ajnr.A0537. PubMed PMID: 17569971.
  11. Keihaninejad S, Heckemann RA, Fagiolo G, Symms MR, Hajnal JV, Hammers A. A robust method to estimate the intracranial volume across MRI field strengths (1.5T and 3T). Neuroimage. 2010;50:1427-37. doi.org/10.1016/j.neuroimage.2010.01.064. PubMed PMID: 20114082. PubMed PMCID: 2883144.
  12. Ertekin T, Acer N, Icer S, Yildirim A. Estimation 0f the Total Brain Volume Using Semi-Automatic Segmentation and Stereology of the Newborns’ Brain MRI. NeuroQuantology. 2013;11(2). doi.org/10.14704/nq.2013.11.2.631.
  13. Wang D, Doddrell DM. MR image-based measurement of rates of change in volumes of brain structures. Part I: method and validation. Magnetic resonance imaging. 2002;20:27-40. doi.org/10.1016/S0730-725X(02)00466-6.
  14. Acer N, Turgut AT, Turgut M, Özsunar Y. Quantification of volumetric changes of brain in neurodegenerative diseases using magnetic resonance imaging and stereology: INTECH Open Access Publisher; 2011.
  15. Acer N, Ilica AT, Turgut AT, Ozcelik O, Yildirim B, Turgut M. Comparison of three methods for the estimation of pineal gland volume using magnetic resonance imaging. ScientificWorldJournal. 2012;2012:123412. doi.org/10.1100/2012/123412. PubMed PMID: 22619577. PubMed PMCID: 3349090.
  16. Tang Y, Whitman GT, Lopez I, Baloh RW. Brain volume changes on longitudinal magnetic resonance imaging in normal older people. J Neuroimaging. 2001;11:393-400. doi.org/10.1111/j.1552-6569.2001.tb00068.x. PubMed PMID: 11677879.
  17. Furlong C, Garcia-Finana M, Puddephat M, Anderson A, Fabricius K, Eriksen N, et al. Application of stereological methods to estimate post-mortem brain surface area using 3T MRI. Magn Reson Imaging. 2013;31:456-65. doi.org/10.1016/j.mri.2012.09.001. PubMed PMID: 23238418.
  18. Mayhew TM, Olsen DR. Magnetic resonance imaging (MRI) and model-free estimates of brain volume determined using the Cavalieri principle. J Anat. 1991;178:133-44. PubMed PMID: 1810922. PubMed PMCID: 1260542.
  19. Sonmez OF, Odaci E, Bas O, Colakoglu S, Sahin B, Bilgic S, et al. A stereological study of MRI and the Cavalieri principle combined for diagnosis and monitoring of brain tumor volume. J Clin Neurosci. 2010;17:1499-502. doi.org/10.1016/j.jocn.2010.03.044. PubMed PMID: 20801042.
  20. Collins DL, Zijdenbos AP, Kollokian V, Sled JG, Kabani NJ, Holmes CJ, et al. Design and construction of a realistic digital brain phantom. IEEE Trans Med Imaging. 1998;17:463-8. doi.org/10.1109/42.712135. PubMed PMID: 9735909.
  21. Thapaliya K, Kwon G-R, editors. Extraction of brain tumor based on morphological operations. Computing Technology and Information Management (ICCM), 2012 8th International Conference on; 2012: IEEE.